From specification to commissioning — complete power continuity solutions engineered for your industry, load profile, and regulatory environment.
Hyperscale and colocation data centers demand UPS solutions that scale dynamically, deliver >99.9999% availability, and integrate with DCIM platforms. PowerSentinel's SentinelPro modular architecture enables online capacity expansion from 30kVA to 3MW within a single frame — with N+1, N+2, and 2N redundancy configurations.
Native SNMP v3, Modbus TCP, and RESTful API interfaces provide real-time power quality data — including input/output voltage, frequency, load percentage, battery state of charge, and total harmonic distortion — directly to your DCIM system without external gateways.
| Parameter | Specification |
|---|---|
| Power Range | 30kVA – 3,000kVA (modular) |
| Classification | VFI-SS-111 per IEC 62040-3 |
| Peak Efficiency | 97.5% (ECO mode), 96.0% (double conv.) |
| Transfer Time | <2ms (zero-interruption VFI) |
| Input PF | ≥0.99 (Active PFC) |
| THD Input | <3% |
| Communication | SNMP v3, Modbus TCP, BACnet/IP |
Pharmaceutical manufacturing and hospital environments impose stringent power quality and validation requirements. PowerSentinel provides UPS systems with full IQ/OQ/PQ documentation packages, 21 CFR Part 11 compatible event logging, and UL 1778 listing — meeting the documentation standards of FDA, EMA, and ANVISA regulated facilities.
Static bypass switches with break-before-make sequencing ensure load transfer without interrupting sensitive analytical instrumentation. Our commissioning team delivers Installation Qualification protocols as part of standard project delivery.
Review P&IDs and equipment schedules; calculate apparent power and determine UPS frame configuration
IQ/OQ/PQ protocols, CE Declaration, UL listing certificate, test reports included at no extra charge
On-site IQ execution, witnessed testing, and final validation report signed by qualified commissioning engineer
Annual PM visits, battery health testing, firmware updates, 24/7 emergency response coverage
PLCs, servo drives, HMIs, and SCADA infrastructure require stable, clean DC power with rapid fault detection. PowerSentinel's SentinelDC range provides 24V/48V/110V DC supplies with <1% output ripple and built-in buffer capacitors for ride-through during brief mains interruptions.
SentinelDC units occupy minimal panel space — 45mm to 120mm width — with integrated DC OK relay contacts for PLC fault signaling.
-40°C to +70°C rated for harsh foundry, outdoor enclosure, and cold storage environments. IP20 to IP67 enclosure variants available.
Up to 32 SentinelDC units can be paralleled for N+1 redundancy — eliminating the DC supply as a single point of failure in critical automation cells.
IEC 61850-compatible DC systems for protection relays and SCADA. Station battery chargers with temperature-compensated charging for vented lead-acid and valve-regulated batteries.
EN 50155 certified traction-environment UPS and DC supplies for signaling, CCTV, and passenger information systems. Wide input voltage acceptance (72–150VDC or 85–300VAC).
ATEX Zone 1 & Zone 2 rated UPS and DC supplies for wellhead, platform control rooms, and pipeline monitoring systems. IECEx international certification for global deployment.